| Especificaciones: |
|
| Power |
+ 24V DC ±10% |
| Bezel |
IP 65 rated Keypad and Touch Screen |
| Operating Temperature |
0o to 50oC |
| Storage Temperature |
-20o to 80oC |
| Humidity |
10% to 85% (Non condensing) |
| Communication Port |
One Serial Port
(RS232 / RS422 / RS485 levels supported) |
| USB Device Port |
As programming and monitoring port |
| USB Host port |
Supports USB Memory drive |
| Type of LCD |
TFT |
| LCD Life |
50000 hrs at 25oC |
| Supported Colors |
32K for bitmaps |
| Immunity to ESD |
as per IEC61000-4-2 |
| Immunity to Fast Transients |
as per IEC61000-4-4 |
| Immunity to Radiated electromagnetic field |
as per IEC61000-4-3 |
| Immunity to Conducted disturbances |
as per IEC61000-4-6 |
| Surge |
as per IEC61000-4-5 |
| Radiated emission |
as per EN55011 |
| Digital Inputs |
Rated Input Voltage
| Rated Input Voltage |
For Normal Input
24 VDC (Max is 28 VDC) |
For High Speed
24 VDC (Max is 28 VDC) |
| Impedance |
4.7 k |
2.3 k |
|
Logic '0' Voltage : 0 to 5 V
Logic ‘1' Voltage : 14 to 28 V |
Rated Input Current at (24 VDC)
| |
For Normal Input
|
For High Speed
|
| Rated Input Current |
4.89 mA |
10 mA |
|
| Digital Outputs (Open Collector) |
| Maximum Load current |
500 mA NPN or PNP. Short circuit protected |
| Voltage drop at ON |
0.4 V or less |
| Digital Outputs (Relay) |
| Relay Rating |
230 V AC, 2 Amp. (Max) 5 Amp per common |
| Analog Inputs |
Resolution
|
12-bit |
Voltage Mode
|
Y |
Input Range
|
-10V to +10V |
Value of LSB
|
For 0-10V : 2.44mV
For +/- 10V : 4.88mV |
Input Impedance
|
200KW |
Accuracy at 25°C
|
0.1% of full scale |
Overall accuracy (–25°C to 55°C) % Full Scale
|
0.3% of full scale |
Frequency Limit (-3db)
|
3.5KHz |
| Behavior upon sensor failure |
Input goes to 0, as if no input is connected |
| Current Mode |
Current Mode
|
Y |
Input Range
|
4mA – 20mA, 0mA - 20mA |
Value of LSB
|
3.906uA |
Input Impedance
|
120W |
Accuracy at 25°C
|
0.2% of full scale |
Overall accuracy (–25°C to 55°C) % Full Scale
|
0.8% of full scale |
Frequency Limit (-3db)
|
15KHz |
| Behavior upon sensor failure |
Input goes to 0, as if no input is connected |
Maximum permissible voltage (surge voltage)
between analog inputs
between analog inputs and reference
|
500V
1000V |
| Reverse Connection Protection |
No |
| Analog Outputs |
Resolution
|
12bit |
Voltage Mode
|
Y |
Output Range
|
0 to +10V |
Value of LSB
|
2.44mV/step |
Output Load minimum
|
1000Ώ |
Accuracy at 25°C
|
0.05% of full scale |
Overall accuracy (–25°C to 55°C) % Full Scale
|
±10ppm/°C |
| Current Mode |
Output Range
|
4mA to 20mA |
Value of LSB
|
3.9umA |
Output Load maximum
|
500Ώ |
Accuracy at 25°C
|
0.13% of full scale |
Overall accuracy (–25°C to 55°C) % Full Scale
|
±10ppm/°C |
| Current Mode |
Output Range
|
0mA to 20mA |
Value of LSB
|
4.8umA |
Output Load
|
500Ώ |
Accuracy at 25°C
|
0.13% of full scale |
Overall accuracy (–25°C to 55°C) % Full Scale
|
±10ppm/°C |